| Philips P/N | Vrwm
(kV) |
Io
(mA) |
Vf
(V) |
If
(mA) |
Ir
(uA) |
Trr
(ns) |
Body | Lead | VMI P/N | VMI P/N Datasheet | VMI Alternate P/N | Exceptions | ||
| BY428 | 1500 | 4000 | 1.95 | 4000 | 150 | 250 | Glass | Axial | 1N6513 | 1N6513 | Not an exact match. Does not meet Io, or physical dimensions | |||
| BY505 | 2 | 85 | 8.5 | 100 | 3 | 100 | Glass | Axial | 1N6531 |
|
||||
| BY584 | 1.5 | 85 | 8.5 | 100 | 3 | 200 | Glass | Axial |
1N6531 |
|
||||
| BY614 | 2 | 50 | 6 | 50 | 3 | 300 | Glass | Axial | 1N6531 |
|
Length dimension differs | |||
| BY715 | 4 | 20 | 28 | 100 | 3 | 100 | Glass | Axial | 1N6533 |
|
Reverse leakage specification differs | |||
| BY716 | 5 | 20 | 28 | 100 | 3 | 100 | Glass | Axial | 1N6535 |
|
Slight difference in physical dimensions | |||
| BY718 | 10 | 4 | 69 | 100 | 3 | 100 | Glass | Axial | M160UFG |
|
||||
| BY8104 | 5 | 20 | 26 | 100 | 3 | 60 | Glass | Axial |
M50FF3 |
|
||||
| BY8106 | 6 | 10 | 36 | 100 | 3 | 60 | Glass | Axial |
1N6535 M160UFG |
|||||
| BY8108 | 10 | 5 | 44.5 | 100 | 3 | 60 | Glass | Axial | MR100FF3 MR100FF5 |
|||||
| BY8110 | 12 | 5 | 54.5 | 100 | 6 | 60 | Glass | Axial |
M160FF3 M160FF5 |
|
||||
| BY8112 | 14 | 5 | 75 | 100 | 3 | 60 | Glass | Axial |
M160FF3 M160FF5 |
|
||||
| BY8114 | 16 | 5 | 82.5 | 100 | 3 | 60 | Glass | Axial | M160FF3 | M160FF3-FF5 | Controlled avalanche | |||
| BY8404 | 4 | 20 | 20 | 100 | 3 | 100 | Glass | Axial | 1N6533 |
|
Slight differences in lead length and high temperature Ir | |||
| BY8406 | 6 | 10 | 25 | 100 | 3 | 100 | Glass | Axial | 1N6535 |
|
Slight differences in lead length and high temperature Ir | |||
| BY8408 | 8 | 5 | 35 | 100 | 3 | 100 | Glass | Axial | 1N6535 |
|
Slight differences in lead length and high temperature Ir | |||
| BY8410 | 10 | 5 | 42 | 100 | 3 | 100 | Glass | Axial | 1N6535 |
|
Slight differences in lead length and high temperature Ir | |||
| BY8412 | 12 | 5 | 52 | 100 | 3 | 100 | Glass | Axial | M160UFG |
|
Slight differences in lead length and high temperature Ir and capacitance | |||
| BY8414 | 14 | 5 | 60 | 100 | 3 | 100 | Glass | Axial | M160UFG |
|
Slight differences in lead length and high temperature Ir and capacitance | |||
| BY8416 | 16 | 3 | 70 | 100 | 3 | 100 | Glass | Axial | M160UFG |
|
Slight differences in lead length and high temperature Ir and capacitance | |||
| BY8418 | 18 | 3 | 77 | 100 | 3 | 100 | Glass | Axial | M180UFG |
|
Slight differences in lead length and high temperature Ir and capacitance | |||
| BY8420 | 20KV | M180UFG |
|
No 20KV replacement available | ||||||||||
| BY8424 | 24KV | M180UFG |
|
No 24KV replacement available | ||||||||||
| BYD47-20 | 2KV | 800 | 2.05 | 1000 | 5 | 300 | Glass | MELF | 1N6531 | 1N6531 | No direct replacement. Differences exist in Vf, Io, and physical dimensions. | |||
| BYD57M | 1 | 400 | 3.6 | 1000 | 5 | 75 | Glass | MELF | MD90U25J |
|
No direct replacement available | |||
| BYV98 | 2 | 1000 | 2.4 | 2000 | 5 | 3000 | Glass | Axial | 1N6513 Z25UFG |
Controlled avalanche and Vf , Trr ratings differ. Slight difference in physical dimensions. | ||||
| BYW97G | 1.4 | 3300 | 1.45 | 5000 | 1 | 500 | Glass | Axial | 1N6513 | Differences in forward current, Vf, and avalanche ratings. Slight difference in physical dimensions. | ||||
| BYX102G | 10 | 360 | 23.9 | 1000 | 15 | 350 | Glass | Axial | Z100FG |
|
Slight differences in physical dimensions and reverse power capability | |||
| BYX104G | 10 | 225 | 52 | 1000 | 15 | 50 | Glass | Axial | Z100FF5 | Controlled avalanche and slight difference in physical dimensions. Z100FF5 has higher Io and Ifsm ratings. X100FF5 has lower Ifsm; Io in oil the same. Lower cost. | ||||
| BYX108G | 4.5 | 340 | 16.5 | 1000 | 15 | 50 | Glass | Axial |
1N6837 1N6839 Z50FF5 Z50FF3 |
Controlled avalanche differs |
||||
| BYX134GPS | 4 | 50 | 7 | 10 | 30 | 3000 | Plastic | Axial | M50SG |
|
M50SG hermetically sealed glass | |||
| BYX90G | 7.5 | 550 | 14.5 | 2000 | 50 | 350 | Glass | Axial | ZR50UFG
ZR100UFG |
|
Not an exact replacement. Differences in rated Vr. | |||
| OF861 | 7 | 40 | 18.5 | 100 | .10 | 200 | Glass | Axial |
1N6527 1N6535 |