Custom Designs
Custom Design Specifications - Print out the .pdf form and fax it to us.
E-mail Design Spec. Form- Fill out the design
form and submit it on-line.
Minimum Information -
1) Output voltage
2) Output current
3) Input voltage
4) Input frequency
5) Package size
6) Environment extremes (temperatures, altitude, humidity)
|
Practical limits exist, which help to pinpoint the design of a custom hybrid multiplier. The following rules of thumb generally apply for custom hybrids:
• AC input voltage: Up to 1,400Vp-p
• AC input frequency: 5kHz to 100kHz
• DC output voltage: 1 to 6kV
• Op. temp. range: -55°C to +125°C
• Relative humidity: 0-100%
• Altitude: 0-space
When requesting a custom hybrid multiplier quotation, please provide the required information listed at the left.
|